Specifications - Power Plant 20

Environment Specification

US/JP

Europe/Asia

Location Indoor use only Indoor use only
Duty Cycle Suitable for continuous operation Suitable for continuous operation
Moisture Sensitivity Not sealed against moisture Not sealed against moisture
Operating Humidity <80%rh <80%rh
Storage Temperature -40C to +40C -40C to +40C
Operating Temperature 0C to 40C 0C to 40C
Max Operating Altitude 12,000’ (3500m) 12,000’ (3500m)
Electrical Supply Nominal Rating 120V 15A 60Hz US
100V 15A 50/60 Hz JP
230V 10A 50/60Hz

Instrument Specification

Unit Dimensions 17” W x 14” D x 11” H (43cm W x 36cm D x 27.9 cm H) 17” W x 14” D x 11” H (43cm W x 36cm D x 27.9 cm H)
Unit Weight 96 lbs ( 43.5kg) 96 lbs ( 43.5kg)
Shipping Dimensions 23” x 22” x 17” ( 58cm x 55.8cm x 43 cm) 23” x 22” x 17” ( 58cm x 55.8cm x 43cm)
Shipping Weight 105 lbs (47kg) 105 lbs (47kg)
Nominal Input Voltage 95 – 145 VAC 200 –285VAC
Maximum Continuous Load 2000VA 2000VA
Maximum Peak Load 3600VA 3600VA
Voltage Regulation >1V >1V
Output Distortion (Resistive Load) <0.5% <0.5%
Output Distortion (Reactive Load) <0.5%
0.1% typical
<0.5%
0.1% typical
Output Impedance <0.005 ohm <0.005 ohm
Noise Reduction 100kHz – 2MHz >80dB 100kHz – 2MHz >80dB
Efficiency @1500 VA >85% >85%
Standby Power Consumption
Input Frequency 45 – 65 Hz 45 – 65 Hz
Under Voltage Limit Continuous -10% of setting 15 sec duration -15% of setting Continuous -10% of setting 15 sec duration -15% of setting
Over Voltage Limit Continuous 5% of setting 15 sec duration 10% of setting Continuous 5% of setting 15 sec duration 10% of setting
Energy Dissipation 2040J 5040J
Peak Current Surge 180,000A 180,000A
Clamp Level 340V 775V
DC Trigger Configuration Tip Positive Tip Positive
DC Trigger Voltage 5 – 15Vdc 5 – 15Vdc