PowerPlants are personal AC generators that provide hard-working, perfected results from the AC power line. Power regeneration uses active components, like those found in large, powerful audio amplifiers, to rebuild the AC power and produce clean, clear, distortion-free, regulated AC to the equipment. The results of feeding your equipment with low output impedance are dramatic: unrestrained dynamics even under the loudest passages, an open, wide soundstage that does not collapse with volume and a naturalness to the music that is remarkable. The 4.3-inch, full color display on the front panel of the P12 allows you to measure distortion, both incoming and outgoing, improvement levels, and power consumption. You can also adjust your settings, such as the turn on/off sequence and the output voltage, as well as turn individual zones on or off, and measure the power quality with either the built-in oscilloscope or the THD analyzer.



Features
Specifications - Power Plant 12
Environment Specification |
US/JP |
Europe/Asia |
Location | Indoor use only | Indoor use only |
Duty Cycle | Suitable for continuous operation | Suitable for continuous operation |
Moisture Sensitivity | Not sealed against moisture | Not sealed against moisture |
Operating Humidity | <80%rh | <80%rh |
Storage Temperature | -40C to +40C | -40C to +40C |
Operating Temperature | 0C to 40C | 0C to 40C |
Max Operating Altitude | 12,000’ (3500m) | 12,000’ (3500m) |
Electrical Supply Nominal Rating | 120V 15A 60Hz US 100V 15A 50/60 Hz JP |
230V 10A 50/60Hz |
Instrument Specification |
||
Unit Dimensions | 17” W x 14” D x 4” H (43cm W x 36cm D x 10.16 cm H) | 17” W x 14” D x 4” H (43cm W x 36cm D x 10.16 cm H) |
Unit Weight | 37 lbs ( 16.7kg) | 37 lbs ( 16.7kg) |
Shipping Dimensions | 24” x 21” x 10” ( 61cm x 53cm x 25cm) | 24” x 21” x 10” ( 61cm x 53cm x 25cm) |
Shipping Weight | 48 lbs (21.7kg) | 48 lbs (21.7kg) |
Nominal Input Voltage | 95 – 145 VAC | 200 –285VAC |
Maximum Continuous Load | 1000VA | 1200VA |
Maximum Peak Load | 3600VA | 3800VA |
Voltage Regulation | 0.5V | 1V |
Output Distortion (Resistive Load) | <0.5% | <0.9% |
Output Distortion (Reactive Load) | <0.5% 0.1% typical |
<0.9% 0.1% typical |
Output Impedance | <0.008 ohm | <0.008 ohm |
Noise Reduction | 100kHz – 2MHz >80dB | 100kHz – 2MHz >80dB |
Efficiency @1200 VA | >85% | >85% |
Input Frequency | 45 – 65 Hz | 45 – 65 Hz |
Under Voltage Limit | US - 90 V JP - 75 V |
174 V |
Over Voltage Limit | US - 144 V JP - 120 V |
275 V |
Energy Dissipation | 1020J | 1270J |
Peak Current Surge | 90,000A | 90,000A |
Max Surge Voltage | 6,000V | 6,000V |
Clamp Level | 340V | 800V |
DC Trigger Configuration | Tip Positive | Tip Positive |
DC Trigger Voltage | 5 – 15Vdc | 5 – 15Vdc |
Standby Power Consumption |
35 Watts |
30 Watts |