Environment Specification |
US/JP |
Europe/Asia |
| Location | Indoor use only | Indoor use only |
| Duty Cycle | Suitable for continuous operation | Suitable for continuous operation |
| Moisture Sensitivity | Not sealed against moisture | Not sealed against moisture |
| Operating Humidity | <80%rh | <80%rh |
| Storage Temperature | -40C to +40C | -40C to +40C |
| Operating Temperature | 0C to 40C | 0C to 40C |
| Max Operating Altitude | 12,000’ (3500m) | 12,000’ (3500m) |
| Electrical Supply Nominal Rating | 120V 15A 60Hz US 100V 15A 50/60 Hz JP |
230V 10A 50/60Hz |
Instrument Specification |
||
| Unit Dimensions | 17” W x 14” D x 8.5” H (43cm W x 36cm D x 21.5 cm H) | 17” W x 14” D x 8.5” H (43cm W x 36cm D x 21.5 cm H) |
| Unit Weight | 73 lbs ( 33kg) | 73 lbs ( 33kg) |
| Shipping Dimensions | 23” x 20.5” x 13.5” ( 58cm x 52cm x 34cm) | 23” x 20.5” x 13.5” ( 58cm x 52cm x 34cm) |
| Shipping Weight | 82 lbs (38kg) | 82 lbs (38kg) |
| Nominal Input Voltage | 95 – 145 VAC | 200 –285VAC |
| Maximum Continuous Load | 1200VA | 1500VA |
| Maximum Peak Load | 3600VA | 3600VA |
| Voltage Regulation | 1V | 1V |
| Output Distortion (Resistive Load) | <0.5% 0.1% typical |
<0.9% 0.2% typical |
| Output Distortion (Reactive Load) | <0.5% 0.1% typical |
<0.9% 0.2% typical |
| Output Impedance | <0.008 ohm | <0.008 ohm |
| Noise Reduction | 100kHz – 2MHz >80dB | 100kHz – 2MHz >80dB |
| Efficiency @1200 VA | >85% | >85% |
| Standby Power Consumption | ||
| Input Frequency | 45 – 65 Hz | 45 – 65 Hz |
| Under Voltage Limit | US - 90V JP - 75V |
174V |
| Over Voltage Limit | US - 144V JP - 120V |
275V |
| Energy Dissipation | 2440J | 3670J |
| Peak Current Surge | 144,000A | 84,000A |
| Max Surge Voltage | 6,000V | 6,000V |
| Clamp Level | 330V | 800V |
| DC Trigger Configuration | Tip Positive | Tip Positive |
| DC Trigger Voltage | 5 – 15Vdc | 5 – 15Vdc |
| Standby Power Consumption |
35 Watts |